Disclosure: we may earn a commission from links on this page, at no cost to you. How we choose filters.

To read a water quality report, find three things first: the detected-contaminants table, the lead and copper results, and the violations section. Compare each detected level with its legal limit and its health goal. Everything else in the report explains where those numbers came from.
Your utility’s annual water quality report, officially a Consumer Confidence Report (CCR), is the most useful free document you can read before buying a filter. It is also written in regulator shorthand. This guide translates it, section by section.
Key takeaways
- The detected-contaminants table is the heart of the report.
- Compare each result with the MCLG (health goal), not only the MCL.
- Lead results come from home taps, so your plumbing matters.
- A violation section that says “none” is the best line in the report.
Where to find your report
Most utilities post the report on their website each summer and mail or email a link to customers. If you pay a water bill, the utility’s name is on it. Renters can ask their landlord or look up the utility that serves their address. Federal rules require community water systems to deliver the report to customers by July 1 each year.
The words and units you will see
Water quality reports reuse the same handful of terms. Once you know them, every table becomes readable.
| Term | What it means in plain English |
|---|---|
| MCL (Maximum Contaminant Level) | The legal limit for a contaminant. Utilities must stay at or below it. |
| MCLG (Maximum Contaminant Level Goal) | The level below which no health risk is expected. Not enforceable, and often lower than the MCL. |
| Action level (AL) | For lead and copper, the level that requires the utility to take extra steps, such as corrosion control. |
| Treatment technique (TT) | A required treatment process used instead of a numeric limit, common for turbidity and microbes. |
| MRDL / MRDLG | The limit and the goal for disinfectants such as chlorine or chloramine. |
| ppm / ppb | Parts per million and parts per billion. One ppm equals 1,000 ppb. |
| Range | The lowest and highest results from all samples during the year. |
| 90th percentile | For lead and copper: 9 out of 10 homes sampled were at or below this level. |
Watch the units closely. A reading of 5 ppb is the same as 0.005 ppm, and reports sometimes switch units between rows.
Reading the detected-contaminants table
This table lists only what was found, not everything that was tested. For each row, look at four columns in this order:
- Highest level detected. The worst result during the year, or the highest running average for contaminants regulated as an average.
- MCL. If the highest level is above it, the report must also list a violation.
- MCLG. The gap between your result and this goal tells you how much room a filter has to improve things.
- Likely source. Natural deposits, farm runoff, industrial discharge or a by-product of disinfection. The source hints at whether the level will change year to year.
Disinfection by-products, such as total trihalomethanes (TTHM) and haloacetic acids (HAA5), often appear near the top. They form when chlorine reacts with natural material in the water. They are regulated as running averages, so a single high sample does not mean a violation.
Lead and copper: the section that depends on your home
Lead rarely comes from the treatment plant. It usually comes from lead service lines, old solder or brass fixtures inside buildings. That is why utilities sample lead at customers’ taps and report the 90th-percentile result, along with how many homes exceeded the action level.
- The health goal (MCLG) for lead is zero.
- The lead action level has been 15 ppb. EPA finalized rule changes in 2024 that lower it to 10 ppb as the new rule phases in, so check which level your report uses.
- The copper action level is 1.3 ppm.
Even when the utility meets the action level, a home with lead pipes can test higher. Many reports now say whether the utility has an inventory of lead service lines and how to check your address.
Violations and the fine print
A violation section that reads “none” means the utility met every monitoring, reporting and treatment requirement that year. If there was a violation, the report must explain what happened, what the utility did about it, and whether you need to take any action.
Also read the paragraphs about vulnerable groups. Reports must include guidance for people with weakened immune systems and information about lead for families with young children.
When the report points to a filter
The report tells you what problem you are solving, if any:
- Chlorine or chloramine taste and smell: a carbon filter, from a certified pitcher to a whole-house system.
- Lead in tap samples, or an older home: a filter certified to NSF/ANSI 53 for lead.
- PFAS, nitrate or arsenic: a certified reverse osmosis system.
- High hardness: a water softener; filters do not remove hardness.
- Nothing above the health goals: you may not need a filter at all.
See your city’s breakdown on our tap water by city page.
What changes next
EPA revised the report rules in 2024. Starting in 2027, systems serving more than 10,000 people must send reports twice a year, and reports must be easier to read, offer translations where needed and say more about lead.
Frequently asked questions
What is a Consumer Confidence Report?
It is the annual water quality report that community water systems must give their customers. It lists the water’s sources, the contaminants detected and how they compare with federal limits.
What does “ND” mean in a water quality report?
ND means “not detected”: the lab did not find the contaminant above the level its test method can measure.
Does a report cover my private well?
No. Reports cover public water systems only. If you have a private well, test it with a certified lab and see our well water guide.
Sources: EPA: Understanding your water quality report · EPA: CCR rule revisions · EPA: Lead and Copper Rule Improvements fact sheet